DIN48 SIZE ANALOG MULTI-LANGE CYCLIC TWIN TIMERS.
UL/C-UL , CE , Lloyd Approved
(PM4H-W)
All types of PM4H-W timer have multi-time range.
16 time ranges are selectable.
1s to 500h (Max. range) is controlled.
| Time unit | sec | min | hrs | 10h | |
|---|---|---|---|---|---|
| Scale | |||||
| 1 | Control time range | 0.1s to 1s | 0.1 min to 1 min | 0.1h to 1h | 1.0h to 10h |
| 5 | 0.5s to 5s | 0.5 min to 5 min | 0.5h to 5h | 5h to 50h | |
| 10 | 1.0s to 10s | 1.0 min to 10 min | 1.0h to 10h | 10h to 100h | |
| 50 | 5s to 50s | 5 min to 50 min | 5h to 50h | 50h to 500h | |

| Type Item | PM4H-W | ||
|---|---|---|---|
| Rating | Rated operating voltage | 100 to 240V AC, 12V DC, 24V AC/DC, 48 to 125V | |
| Rated frequency | 50/60Hz common (AC operating type) | ||
| Rated power consumption | Approx. 10VA (100 to 240V AC) Approx. 2.5VA (24V AC) Approx. 2W (12V DC, 24V DC, 48 to 125V DC) | ||
| Output rating | 5A 250V AC (resistive load) | ||
| Operation mode | Cyclic (OFF-start/Twin operation) | ||
| Time range | 1s to 500h 16 time ranges switchable (T1, T2time setting individually) | ||
| Time accuracy Note:) | Operation time fluctuation | ±0.3% (power off time change at the range of 0.1s to 1h) | |
| Setting error | ±5% (Max. setting time value) | ||
| Voltage error | ±0.5% (at the operating voltage changes between 85 to 110%) | ||
| Temperature error | ±2% (at 20°C ambient temp. at the range of -10 to +50°C/ +14 to +122 °F) | ||
| Contact | Contact arrangement | Timed-out 2 Form C | |
| Contact resistance (Initial value) | Max. 100mohm (at 1A 6V DC) | ||
| Contact material | Silver alloy | ||
| Life | Mechanical | 2×107 | |
| Electrical | 105(at rated control capacity) | ||
| Electrical function | Allowable operating voltage range | 85 to 110% of rated operating voltage (at 20°C coil temp.) | |
| Insulation resistance (Initial value) | Min. 100Mohm Between live and dead metal parts Between input and output Between contacts of different poles Between contacts of same pole (At 500V DC) | ||
| Breakdown voltage (Initial value) | 2, 000Vrms for 1 min Between live and metal parts 2, 000Vrms for 1 min Between input and output 2, 000Vrms for 1 min Between contacts of different poles 1, 000Vrms for 1 min Between contacts of same pole | ||
| Min. power off time | 300ms | ||
| Max. temperature rise | 55°C/ 131 °F | ||
| Mechanical function | Shock resistance | Functional | Min. 98m/s2(4 times on 3 axes) |
| Destructive | Min. 980m/s2(5 times on 3 axes) | ||
| Vibration resistance | Functional | 10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes) | |
| Destructive | 10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes) | ||
| Operating condition | Ambient temperature | -10 to +50°C/ +14 to +122 °F | |
| Ambient humidity | Max. 85%RH | ||
| Atmospheric pressure | 860 to 1, 060hPa | ||
| Ripple factor (DC type) | 20% | ||
| Others | Protective construction | IP65 on front panel (using rubber gasket ATC 18002) (only for IP65 type) | |
| Weight | 120g/ 4.233 oz (Pin type), 130g/ 4.586 oz(Screw terminal type) | ||